Code: RN5EFUK03GY
Code: RN5EFUK03GY
  • To ask a question
Conductor surface Bare
Diameter conductor, mm 0.51
Conductor category Class 1 = solid
Number of cores 8
Stranding element Pairs
Core insulation material Polyolefin
Core identification Colour
Screen over stranding element Foil
Screen over stranding None
Protective sheath No
Material outer sheath Polyolefin
Colour outer sheath Grey
Flame retardant According to IEC/EN 60332-3-22
Outer diameter approx., mm 6.4
Permitted cable outer temperature during assembling/handling, °C -10...60
Permitted cable outer temperature after assembling without vibration, °C -20...60
Category 5E
NVP value, % 68
AWG-size 24
UV resistant No
Conductor material Copper
Suitable for underground installation No
Cable make-up (type) F/UTP
Nominal cross section conductor, mm² 0.203
Number of stranding elements 4
Low smoke (according to BS EN 61034-2) Yes
Product type Copper cable
System category CAT 5e
Color gray
System type shielded
Scope of use Plenum Rated Cable
Cable type F/UTP
Standards for fire safety LTx
19 мм ≥ 10 Ø
Wire in insulation outer diameter 1,07 mm
Flammable load volume, l/m 0.0188
Dielectric cruciate separator No
Conductor design Solid
Conductor material copper
Wave impedance, Ohm 100
Electrical resistance of the core (at 20 °C), Ohm: 9,0 ·100m
Wire insulation resistance, Ohm (20° C) 5000·km
DC test voltage, kV/1 min 1
Nominal voltage AC/DC, V 48/72
Applications 10BASE-T, 100BASE-T, 1000BASE-T, PoE, PoE+ (802.3 af, 802.3 at)
Standarts ISO 11801-1, IEC 61156-5, IEC 61156-9, TIA/EIA-568.2-D, EN 50173